5. System Diagnostics

System diagnostics may be performed using the status and diagnostics indicators on the

control module and sensors.

5.1 Diagnostics/Status Indicators

NOTE: Status indicators appear to “freeze” if the controller is configured for Gate or Host

mode (Section 4.4), and no signal is present to cause a scan update.

Bright, easy-to-see LED indicators on both sensors and on the front panel of the

control module provide an ongoing display of the system’s operating status.

Control Module:

Output (steady red) indicates Output #1 energized.

Alarm (flashing red) indicates Output #2 energized. This output may be assigned to an

analysis mode, or it may be used as a System Diagnostics alarm or as a Trigger alarm

to gate another A-GAGE MINI-ARRAY System.

Gate (steady red) displays the status of the Gate input.

Alignment: (steady green) indicates proper emitter/receiver alignment and a clear,

unblocked light screen. This indicator is ON when either the green or both the green

and yellow LEDs of the receiver are ON.

Diag 1, Diag 2, Diag 3: These three Diagnostics indicators are used in combination to

determine System status, as shown in the following table.

Diag 1 (Green) Diag 2 (Red) Diag 3 (Red)

Condition

ON

OFF

OFF

Normal operation

ON

ON

OFF

Receiver error

ON

OFF

ON

Emitter error

ON

ON

ON

Emitter/receiver mismatch

OFF

ON

OFF

Controller error

OFF

OFF

ON

EEPROM error

OFF

ON

ON

ROM/RAM error

Network Status Indicator: Bi-colored (red/green) LED indicates network status.

Steady Green

Online, connected to Master.

Flashing Green On-line, address and baud rate OK

Steady Red

Critical network fault or duplicate node address detected

Flashing Red

Connection timeout

OFF

No network power, or offline

Emitter:

Operational (steady red) LED indicates power to the emitter is ON.

Receiver:

Blocked (steady red) LED indicates some of the array beams are blocked.

Marginal (steady yellow) LED indicates that array alignment is marginal.

Alignment: (steady green) LED indicates that array alignment is satisfactory.

MINI-ARRAY CONTROLLER for DeviceNet

POWER

MACNXDN1

NETWORK

STATUS

1

1

V+

16 - 30V dc

1.2A MAX

EMTR

RCVR

+12V

BR

BU

BK

5 Wires

30V

150mA Max

OUT1

10-30V dc

GATE

30V

150mA Max

ALARM

WH

NC

+

NC

COM DRN

T/R

2 3 4 5 6 7 8 9 10 11 12 13 14 15 D5 D4 D3 D2 D1

V-

F1

T/R

V+

BR

BU

BK

5 Wires

WH

CAN_H SHIELD

V-

CAN_L

D

IA

G

1

D

IA

G

2

D

IA

G

3

O

U

T1

A

LA

RM

G

AT

E

A

LI

G

N

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Align

Diag1

Diag2

Diag3

Gate

Alarm

Out1

Figure 5-1. A-GAGE MINI-ARRAY with

DeviceNet System diagnostics

and status indicators