4.6 Scan Analysis Mode Selection

The control module may be programmed, if desired, for any one or two of eight Scan

Analysis (measurement) Modes. Each selected mode may be assigned individually to

an output. The beams in the array are numbered in sequence, with beam #1 located at

the cabled end of the emitter and the receiver. Factory Default Scan Analysis Mode is

Disabled for both outputs #1 and #2; at least one output must be changed to another

option before System will operate.

“Beam Location” Modes

•   First Beam Blocked (FBB): The control module identifies the location of the First

Beam Blocked.

•   First Beam Made (FBM): The control module identifies the location of the First

Beam Made (unblocked).

•   Last Beam Blocked (LBB): The control module identifies the location of the Last

Beam Blocked.

•   Last Beam Made (LBM): The control module identifies the location of the Last

Beam Made (unblocked).

“Beam Total” Modes

•   Total Beams Blocked (TBB): The control module totals the number of blocked

beams.

•   Total Beams Made (TBM): The control module totals the number of made

(unblocked) beams.

Contiguous Beams Blocked (CBB): The control module identifies the largest number

of consecutively blocked beams.

Contiguous Beams Made (CBM): The control module identifies the largest number

of consecutively made beams.

The Analysis Mode(s) selected may be assigned to either or both of the available

outputs. Each output can be set for MEAS1, MEAS2, MEAS1 Inverted or MEAS2

Inverted. (The Invert option is selected separately from the MEAS1/MEAS 2

selection.)

Figure 4-2. Examples of MINI-ARRAY scan

analysis modes

Last Beam Made (LBM)

First Beam Made (FBM)

Receiver

Emitter

8

16

24

32

40

48

Last Beam Blocked (LBB)

First Beam Blocked (FBB)

Receiver

Emitter

8

16

24

32

40

48

Total Beams Made (TBM)

Total Beams Blocked (TBB)

Receiver

Emitter

8

16

24

32

40

48

In Last Beam Blocked mode,

last beam is #43 of 48

In First Beam Blocked mode,

first beam is #15 of 48

In Last Beam Made mode,

last beam is #37 of 48

In First Beam Made mode,

first beam is #26 of 48

In Total Beams Made mode,

34 of 48 possible beams are

made

In Total Beams Blocked mode,

14 of 48 possible beams are

blocked