2 system features, System description, Din-rail-mountable control module – Banner A-GAGE MINI-ARRAY Series User Manual

Page 6

Advertising
background image

System Description

6

Banner Engineering Corp. • Minneapolis, U.S.A.

Website: http://www.baneng.com • Tel: 888.373.6767

1.2 System Features

Built-in features simplify the operation of the A-GAGE MINI-ARRAY System. Emitters and

receivers, available in a choice of two resolutions and 10 lengths, provide the right size

and precision needed for many applications. Programmable beam blanking

accommodates machine components or other fixtures that must remain in or move

through the light screen. Blanking is set using the included EDS file and the user’s

DeviceNet configuration tool.

Built-in diagnostic programming and easy-to-see indicators on the sensors and the

control module simplify alignment and troubleshooting (Figure 1-2). The emitter has a

red LED that signals proper operation. The receiver has three bright LEDs: green

signals that the sensors are properly aligned; yellow signals marginal alignment; and

red signals misalignment or a blocked condition. The control module has seven

System Status LEDs that indicate conditions such as output(s) conducting, Gate signal

received, beam alignment and/or blocked beams. In addition, a bi-color (red/green)

Network Status LED indicates whether the system is online with the DeviceNet network

and whether there are problems.

The A-GAGE MINI-ARRAY System provides a wide selection of sensing and output

options, including: measurement (“scan analysis”) modes; scanning methods that can

determine the target object’s location, overall size, total height or total width; and

numerous output options. Scanning may be continuous or controlled by a host

process controller or a gate sensor.

Blanking feature allows the user to configure any number of beams to be “blanked.” In

effect, blanking causes the affected beams to be made “blind” to activity within the

array.

Figure 1-2. A-GAGE MINI-ARRAY with DeviceNet System features

DIN-Rail-Mountable Control Module

MINI-ARRAY CONTROLLER for DeviceNet

POWER

MACNXDN1

NETWORK

STATUS

1

1

V+

16 - 30V dc

1.2A MAX

EMTR

RCVR

+12V

BR

BU

BK

5 Wires

30V

150mA Max

OUT1

10-30V dc

GATE

30V

150mA Max

ALARM

WH

NC

+

NC

COM DRN

T/R

2 3 4 5 6 7 8 9 10 11 12 13 14 15 D5 D4 D3 D2 D1

V-

F1

T/R

V+

BR

BU

BK

5 Wires

WH

CAN_H SHIELD

V-

CAN_L

D

IA

G

1

D

IA

G

2

D

IA

G

3

O

U

T1

A

LA

RM

G

AT

E

A

LI

G

N

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Red

Operational

LED

Network Status Indicator

Green Blocked LED

Red Marginal

Alignment LED

Yellow

Alignment LED

Diagnostic/Status Indicators

(see Section 5.1)

Advertising