Specifications – Banner DUO-TOUCH Run Bar with STB Buttons User Manual

Page 10

Advertising
background image

Specifications

Power

Supply Voltage and Current: 10 to 30 V dc
Power Consumption: approx. 1.8 W @ 24 V dc (with no output load),

for each STB
Supply Protection Circuitry: Protected against transient voltages and

reverse polarity

Connections

Models STBVP6-RB1/-RB2 and -RB1E02/-RB2E02: Terminal strip

connections inside run bar housing (STBs are pre-wired). E-stop button

and EZ-LIGHT indicator (if used) are wired separately.
Models STBVP6-RB1Q8/-RB2Q8: 8-pin Mini-style quick-disconnect

fitting

Construction

STB Buttons: Totally encapsulated, non-metallic enclosure; black

polyetherimide yoke housing (see Application Note below); fiber-

reinforced polyester base; electronics fully epoxy-encapsulated.
E-Stop Button: Polyamide red button with metal base.
Run Bar Housing: 13 ga (0.090") cold rolled steel with powder coat

paint; polypropylene copolymer STB mount.

Ambient Light Immunity

Up to 100,000 lux

EMI/RFI Immunity

Immune to EMI and RFI noise sources, per IEC 947-5-2.

Application Notes

The STB’s polyetherimide upper housing will become brittle with

prolonged exposure to outdoor sunlight. Window glass effectively filters

longer wavelength ultraviolet light and provides excellent protection

from sunlight. Avoid contact with strong alkalis, hydrocarbons and

fuels. Clean periodically using mild soap solution and a soft cloth.

(Polycarbonate STB models are also available for use with the Run Bar;

contact Factory for assistance.)

STB Indicators - 2 Green LEDs

Power: ON – power applied
Output/fault: ON – button is activated
Output/fault: OFF – button is deactivated
Output/fault: Flashing – internal fault or blocked button on power-up

detected

Outputs

Configuration: Complementary PNP (sourcing) open-collector

transistors
Protection Circuitry: Protected against false pulse on power-up;

overload and short-circuit protection.
Response Time: 20 milliseconds ON/OFF

Output Rating

Maximum load: 150 mA
On-state saturation voltage: Less than or equal to 15 V @ full load
Off-state leakage current: Less than 1 μA

Environmental Rating

STBVP6-RB1 Run Bar Models meet IP20
STBVP6-RB2 Run Bar Models meet IP65

Operating Conditions

Temperature: 0º to +50º C (+32º to +122º F)
Maximum relative humidity: 90% @ +50º C (non-condensing)

Certifications

STB Buttons:

STBVP6-RB2...Run Bars:

38.0

[1.50"]

23.0

[0.91"]

4X 5/16-18

Threaded

Insert

4X 6.2

[0.24"]

139.2

[5.49"]

Ø31.0 [1.22"]

Knockout

26.3 [1.04"]

3X Ø23.0
[0.91"]
Knockout

76.0

[2.99"]

34.0 [1.34"]

53.0 [2.09"]

50.3 [1.98"]

137.3

[5.41"]

4X Ø8.9

[0.35"]

CL

CL

CL

CL

CL

Ø22.0 [0.87"]

(1/2" NPT)

Knockout

Ø28.0 [0.87"]
(3/4" NPT) Knockout

Ø22.0 [0.87"]

(1/2" NPT)

Knockout

Ø22.0 [0.87"]

(1/2" NPT)

Knockout or

QD Connector

Ø28.0 [0.87"]
(3/4" NPT) Knockout

126.0

[4.96"]

474.0

[18.66"]

87.0

[3.43"]

Figure 12. STBVP6-RB1 Dimensions