Figure 5. Use the slots in the run bar housing to hold the cover for the terminal connection

8-Pin Mini-Style Output QD Connector

Male Face View

Mating Cable: QDS-8..C

SAE H1738-2

Alternate Color 1

Pin

Color

Function

1

2

3

8

7

6

5

4

Figure 6. 8-pin Mini-style QD Connection

1

brown

+24 V dc

orange

2

orange/black

N.O. STB2

blue

3

orange

N.C. STB2

white/black

4

white

N.C. STB1

black

5

black

N.O. STB1

white

6

blue

0 V dc

red

7

green/yellow

Gnd/PE

green

8

violet

Not Connected (future use)

red/black

Connection of STB Touch Buttons

To maintain a Type IIIC / Category 4 connection, both the normally open and the normally closed outputs of each STB

button must be connected to a two-hand control system or module (e.g., Banner model AT-FM-10K, AT-..M-13A,

AT-..M-11KM or the Banner Safety Controller SC22-3) that meets the requirements listed in the Applications section and

monitors the STB outputs such that if they are not in a complementary state (one open/non-conducting and one closed/

conducting) the system will lock out and prevent further operation until the fault is repaired.

The +24 V dc supply power for the STB buttons must be the same supply that powers the two-hand control system or

module. If a DUO-TOUCH SG safety module is used, use terminals Z1 and Z2 for supply voltage for the STB buttons.

1 Listed as a customer courtesy. Verify suitability of these cables for each application.