The full functionality of the EZ-ARRAY is available by making
use of the PC interface (the graphic user interface, or “Banner
Sensors GUI”). Refer to Section 1 for a full description of the
available sensing modes and other features.

The sensor is easily configured using a Windows

®

menu-

style program via the Banner Sensors GUI software and a
PC-compatible computer (running Windows XP or 2000; GUI
software version 1.2 will also be compatible with Vista

®

).

5.1 Supplied Software

The PC interface software for configuring the EZ-ARRAY is
included on the CD packed with the receiver, entitled Banner
Sensors GUI (p/n 76978).

For the most recent software version, visit

www.

BannerEngineering.com

and enter “Banner Sensors GUI” in the

search field. Install the software (version 1.1 at this writing) onto
your hard drive; the installer will automatically load the software
into a folder titled “Banner Engineering\Banner Sensors GUI”
onto your computer. If the CD is used, inserting it into your CD
drive will auto-launch the GUI installation and place the icon
onto your desktop.

Double-click on the Banner Sensors GUI icon

to launch

the program. The main menu screen appears. Verify that
A-GAGE

®

EZ-ARRAY is displayed in the Select a Sensor field

of the screen.

5.2 Communications Connections

Connect the serial cable from your receiver to your PC, using an
RS485-to-RS232 adapter, such as the model INTUSB485-1 USB
serial adapter listed in Section 2.2. (Instructions for configuring
the adapter are included with the packaging for the adapter.)

An operating EZ-ARRAY system must be connected before the
software displays will open.

5.3 Accessing the GUI

With the sensor pair powered up and connected to your PC (as
described in Section 5.2), go to Sensor > Connect (Ctrl + N).

The Alignment/Status screen appears, providing a snapshot of
the current sensing alignment status, including the status of each
array beam, total numbers of blanked, made and blocked beams,
the selected measurements and their values (see Figure 5-2).

The Alignment/Status screen has three pull-down menus:
Sensor, Options, and Help.

Sensor Menu (Alignment/Status screen)

When the Alignment/Status screen is active, the Sensor menu
provides the options Setup (Ctrl + S), which is used to modify
or view a sensor configuration, Connect/Disconnect (Ctrl + N),
which connects (or disconnects) the PC to the sensor, and Exit
(Ctrl + Q). When a setup screen view is active, the Sensor menu
has other options (see Figures 5-3 and 5-5).

NOTE:

Most GUI Setup options are not available until the
Connect function has linked the PC to a sensor pair.

5. Using the PC Interface (Banner Sensors GUI)

Figure 5-2. EZ-ARRAY Alignment/Status screen

Verify that A-GAGE

®

EZ-ARRAY

is displayed in the
Select a Sensor fiel
d

Click here to
exit program

Gray circles
denote blanked
beams in the array

Red circles
denote blocked
beams

Green circles
denote “made”
(clear) beams

Figure 5-1. Banner Sensors GUI (PC Interface) main menu screen