The ALL Measurements section contains the current values of
all the available measurements. The ALL Measurements data
can be read after every third scan.

Table A–36. ALL Measurements

Input Registers

Member Name

30500

FBB

30501

LBB

30502

TBB

30503

TRN

30504

CBB

30505

FBM

30506

LBM

30507

TBM

30508

CBM

30509

MBB

30510

OD

30511

ID

30512

CFBB

30513

CLBB

30514

O1 FBB

30515

O1 LBB

30516

O2 FBB

30517

O2 LBB

30518

O3 FBB

30519

O3 LBB

30520

CARPET NAP

30521

AO1 PEAK

30522

AO2 PEAK

30523

CARPET EDGE

30524

SPECIAL

Table A–37. Measurements (ALL)

Range

Description

0-1920

Measurements are represented in 4x channel
resolution

Example A–6. Reading ALL Measurements

Request

Response

Field Name

(Hex)

Field Name

(Hex)

Slave Address

41

Slave Address

41

Function

04

Function

04

Starting Address
(HIGH Byte)

77

Byte Count

32

Starting Address
(LOW Byte)

24

Register 30500
(HIGH Byte)

00

Quantity of Registers
(HIGH Byte)

00

Register 30500
(LOW Byte)

00

Quantity of Registers
(LOW Byte)

19

Register 30501
(HIGH Byte)

00

CRC (LOW Byte)

64

Register 30501
(LOW Byte)

00

CRC (HIGH Byte)

BF

Register 30524
(HIGH Byte)

00

Register 30524
(LOW Byte)

00

CRC (LOW Byte)

28

CRC (HIGH Byte)

C0

To read ALL Measurements, a read input registers request is
sent starting at address 30500, and requesting 25 registers.

AO1 PEAK and AO2 PEAK Measurements

The AO1 PEAK and AO2 PEAK measurements store the
minimum/maximum values of Analog Output 1 and Analog
Output 2 respectively. When the EZ-ARRAY’s Analog Outputs
are configured to have Peak Detect = Enabled and Peak
Detect Reset = External Communications, then reading these
measurements will reset the Analog Output Peak Detect value.
To enable this mode of operation, the Analog Output’s Config
Flags register (address 40026 – AO1, address 40030 – AO2)
must be configured as shown in Example A–7.