Appendix, General configuration – Banner EZ-ARRAY USB Serial Adapter User Manual
Page 39

P/N 130426 Rev. C
37
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
A-GAGE EZ-ARRAY
Instruction Manual
Appendix
Example A–4. Writing Blanking Configuration to Blank the First
2 Channels
Request
Response
Field Name
(Hex)
Field Name
(Hex)
Slave Address
41
Slave Address
41
Function
10
Function
10
Starting Address (HIGH
Byte)
9C
Starting Address
(HIGH Byte)
9C
Starting Address (LOW
Byte)
43
Starting Address
(LOW Byte)
43
Quantity of Registers
(HIGH Byte)
00
Quantity of Registers
(HIGH Byte)
00
Quantity of Registers
(LOW Byte)
17
Quantity of Registers
(LOW Byte)
17
Quantity of Bytes
2E
CRC (LOW Byte)
51
Register 40003 (HIGH
Byte)
00
CRC (HIGH Byte)
43
Register 40003 (LOW
Byte)
03
Register 40004 (HIGH
Byte)
00
Register 40004 (LOW
Byte)
00
…
…
…
…
Register 40025 (HIGH
Byte)
00
Register 40025(LOW
Byte)
00
CRC (LOW Byte)
3A
CRC (HIGH Byte)
96
To Blank the first 2 channels, the Blanking 1-16 register (address
40003) is set to the two-byte value of 0x0003 (3 decimal).
General Configuration
The General Configuration contains the general settings for the
EZ-ARRAY.
Table A–6. General Configuration
Holding Register
Address
MASK
Member Name
40046
LOW BYTE
Emitter Power
40046
HIGH BYTE
Gain Method
40047
LOW BYTE
Low Contrast Sensitivity
40047
HIGH BYTE
HW Interface Flags
40048
LOW BYTE
Measurement 1
40048
HIGH BYTE
Measurement 2
40049
RESERVED
40050
Number of Dirty Channels
40051
Time of Service
40052
Table A–7. Emitter Power
Value
Function
Description
0
Disabled
Disabled
1
Level 1
Power Setting 1 (Lowest)
2
Level 2
Power Setting 2
3
Level 3
Power Setting 3
4
Level 4
Power Setting 4
5
Level 5
Power Setting 5
6
Level 6
Power Setting 6
7
Level 7
Power Setting 7
8
Level 8
Power Setting 8
9
Level 9
Power Setting 9
10
Level 10
Power Setting 10
11
Level 11
Power Setting 11 (Highest)
Table A–8. Gain Method
Value
Status
Description
1
High-Excess Gain
Fixed thresholds for maximum
excess gain
2
Low Contrast
Adjustable percentage-based
thresholds (Straight Scan only)