Pc interface, A-gage ez-array, Instruction manual – Banner EZ-ARRAY USB Serial Adapter User Manual
Page 34

32
P/N 130426 Rev. C
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
A-GAGE EZ-ARRAY
Instruction Manual
PC Interface
(Settings are nearly
identical for output 2,
with only minor variation)
Sensor > Setup (Ctrl + S) > Analog Output Config View*
(Not available until Connect is performed)
* Use drop-down arrow at right-hand side of the Current View field to quickly move to another view.
B
A01 Status
Enabled
Disabled
A01 Null Output
If restoring back to factory
defaults, record this value first
A01 Span Output
If restoring back to factory
defaults, record this value first
A01 Slope
Positive
Negative
A01 Measurement
Meas 1 selection
(Default for output 1)
Meas 2 selection
(Default for output 2)
A01 Peak Reset
A01 Zero Value
Hold
Minimum
Maximum
Fast
Medium
Slow
A01 Filter Speed
A01 Peak Detect
Disabled
Minimum
Maximum
Factory-calibrated numeric
value from 0 to 4095
Auto
External Comm
Factory-calibrated numeric
value from 0 to 4095
Analog Output 1
Analog Output 2
B
NOTE: Underlined options
designate default settings.
Sensor > Setup (Ctrl + S) > Discrete Output Config View*
(Not available until Connect is performed)
* Use drop-down arrow at right-hand side of the
Current View
field to quickly move to another view.
C
D01 Status
D01 Measurement
D01 Demodulation
Numeric value from 1 to 250
D01 Hysteresis Low
Numeric value from 0 to 479
D01 Threshold Low
Numeric value from 1 to 480
D01 Threshold High
Numeric value from 1 to 480
D01 Hysteresis High
Numeric value from 2 to 481
D01 Polarity
(Default polarity depends on model,
but can be switched; reverting to
factory default will result in a PNP
setting, regardless of model)
D01 Mode
(Default setting is for
complementary outputs)
Measurement Model Selected
(Either discrete output)
Normally Open
(Default for output 1)
Normally Closed
(Default for output 2)
Alarm/Health Status Mode Selected
(Discrete output 2 only)
D02 Type
Available for output 2 only
(Settings are nearly
identical for output 2,
with only minor variation)
Discrete Output 1
Discrete Output 2
C
NOTE: Underlined options
designate default settings.
Enabled
Disabled
NPN
PNP
Meas 1 selection
Meas 2 selection
Measurement
Alarm/Health Status
Health
Alarm
Figure 5-12. PC Interface configuration overview, part 3 of 7
Figure 5-12. PC Interface configuration overview, part 4 of 7
Sensor > Setup (Ctrl + S) > Comm Config View*
(Not available until Connect is performed)
* Use drop-down arrow at right-hand side of the
Current View
field to quickly move to another view.
D
Address (1-247)
Parity
Numeric value from 1 to 247
(Factory default
65)
Compliant
Extended
Modbus Timeouts
(Relaxes timing requirement to permit
communication with slower devices)
None
Even
Odd
9600
19200
38400
Baud Rate
D
Comm
Configuration
NOTE: Underlined options
designate default settings.
Sensor > Setup (Ctrl + S) > Part Number and Version Info View*
(Not available until Connect is performed)
* Use drop-down arrow at right-hand side of the
Current View
field to quickly move to another view.
E
Receiver Info
Receiver Part Number
Read-only indication
Receiver Firmware Part Number
Read-only indication
Receiver Firmware Version
Read-only indication
Comm Info
Comm Firmware Part Number
Read-only indication
Comm Firmware Version
Read-only indication
Receiver Datecode
Read-only indication
Emitter Info
Emitter Firmware Part Number
Read-only indication
Emitter Firmware Version
Read-only indication
Emitter Datecode
Read-only indication
E
System
Info
NOTE: Underlined options
designate default settings.
Figure 5-12. PC Interface configuration overview, part 6 of 7
Figure 5-12. PC Interface configuration overview, part 5 of 7