The uct screens, Register view, The uct screens register view – Banner SureCross DX80 Wireless Networks User Manual

Page 4

Advertising
background image

The UCT Screens

Register View

Use the Register View screen to graphically display specified Node I/O values. Up to three values can be graphically displayed as either
a dial, a thermometer, or a discrete on/off status.

To begin configuring your graphic displays, click on the Settings button. A setup screen with three tabs opens. To configure your graphi-
cal displays, begin with the I/O Setup tab. The Node register data displaying in the table on the left side of the Status screen is selected
using the I/O Setup screen.

Read Registers

Read Button: Click the Read button to load the current settings from the devices.

Read Frequency: Select Manual or Auto to determine how often registers values are read from the selected Node. To automatically
update the values, select the Auto button and enter in a read frequency in seconds. The auto read frequency can only be changed when
the Auto checkbox is unselected.

Write Registers

To write to specific registers:

1. Select a device to write to from the dropdown list.
2. Select the appropriate I/O (9 through 16) checkbox and enter a value into the selection box.
3. Click the Write button to write the values to the selected device.

Gauge Parameters

Select Show Decimal, Show Hex, and/or Show Values to control how the register information is displayed in the table on the left side of
the screen. In the screen shot shown, the register values are displayed in decimal.

Gauge Setup Button: To customize the information displayed on the gauges, click the Gauge Setup button and configure your displays
using the tabs.