Maintenance Bus
Maintenance Bus
The Cisco XR 12404 router maintenance bus and MBus modules manage all of 
the maintenance functions of the system. The MBus consists of two separate 
busses (providing MBus redundancy). Each MBus is linked to all of the following.
•
Line cards
•
Route Processor
•
CSF card
The MBus module located on each component, communicates over the MBus and 
is powered by +5 VDC directly from the fabric card. The MBus performs the 
functions of power-on/off control for each component, component (device) 
discovery, code download, diagnostics, and environmental monitoring and 
alarms.
Power-On/Off Control
Each MBus module directly controls the DC-to-DC converters on the component 
it is mounted on based on commands the component receives from its on-board 
EPROM and from the route processor. Each MBus module is tied directly to 
+5 VDC from the consolidated fabric card.
When power is applied to the Cisco XR 12404 router, all MBus modules 
immediately power on. The MBus modules on the route processor and CSF card 
immediately turn on the DC-to-DC converter, powering up the respective card. 
The line card MBus module waits to power on the line card until it receives a 
command from the route processor.
Component Discovery
The route processor can determine the system configuration using the MBus. A 
message is sent from the route processor over the MBus requesting all installed 
devices to identify themselves. The response back provides component type, line 
card slot number, and CSF card slot number.