Cisco XR 12404 User Manual

Page 147

Advertising
background image

5-23

Cisco XR 12404 Router Installation Guide

OL-13830-02

Chapter 5 Maintaining the Router

Removing and Replacing a DC PDU

Step 3

Loosen the terminal block screws to disconnect the positive, negative, and ground
wires from the DC PDU terminal block of the faulty PEM (

Figure 5-14

).

Warning

To prevent injury and damage to the equipment, always remove the source DC
power leads and ground from the power shelf terminals in the following order:
(a) negative (–), (b) positive (+), (c) ground.

Caution

Before removing wires, be sure to note the color for each type of wire (positive,
negative, and ground). Because there is no color code standard for source DC
wiring, you must be sure which power wires are connected to the proper positive
(+) and negative (–) terminal ports. Typically, green (or green and yellow) indicate
a ground wire, while power wire leads may be labeled positive (+) or negative (–).
Because this is not always the case, the safest way to indicate the polarity of a wire
is to note its color and identify it as described in this procedure.

Figure 5-14

DC PDU Terminal Block

1

Negative port

3

Ground port

2

Positive port

4

Terminal port connector screws

66949

+

GND

1

4

2

3

todd.book Page 23 Monday, March 16, 2009 2:47 PM

Advertising