A-7

Cisco XR 12404 Router Installation Guide

OL-13830-02

Appendix A Technical Specifications

Compliance Information

Conducted RF Immunity

EN61000-4-6:1996+

ENV50141:1993

AC power line

DC power line

Signal lines

Level 3/10V/A

(150kHz-80MHz)

Voltage Dips + Sag

Interruptions

AC Power Lines

EN61000-4-11:1995

AC power lines

30% 10 ms (0.5 Period)/B

30% 5000ms (25 Periods)

60% 100 ms (5 Periods)/C

60% 1000 ms (50 Periods)

>95% 10ms (0.5 Period)/C

>95% 5000 ms (250 Periods)

Table A-6

Network Equipment Building Systems—NEBS

NEBS Requirements

SR-3580—NEBS criteria levels (Level 3-compliant)

GR-1089-Core—NEBS EMC and safety

GR-63-Core—NEBS physical protection

Table A-7

European Telecommunication Standards Institute—ETSI

ETSI Specifications

ETS 300 386-1—Levels for equipment with a “high priority of service” that is
installed in “locations other than telecommunication centers.”

ETS 300 386-2:1997—Levels for equipment with a “high priority of service”
that is installed in “locations other than telecommunications centers.”

ETSI 300 132-2: September 1996—DC power supply interfaces at the input to
telecommunications equipment Sections 4.8, 4.9.

Table A-5

Immunity Tests (continued)

Test Type or Specification

Applies to

Class/Level/Criteria