Appendix A Technical Specifications

Compliance Information

A-6

Cisco XR 12404 Router Installation Guide

OL-13830-02

ETSI

EN 300386-2/EN55022

B

(Noncentral office)

1. Up to 40 GHz

Table A-5

Immunity Tests

Test Type or Specification

Applies to

Class/Level/Criteria

Electrostatic Discharge

EN61000-4-2:1995

System/enclosure

Level 4/8KV contact, 15KV air/B

Radiated Immunity

IEC61000-4-3:1995

ENV50140:1993

System/enclosure

Level 3/10V/m/A

1KHz 80% AM

(80MHz - 1 GHz)

Fast Transients

EN61000-4-4:1995

AC power lines

DC lines

Signal lines

Level 4/4KV 2.5 kHz Rep Freq/B

Level 4/4KV 2.5 kHz Rep Freq/B

Level 4/1KV 5kHz Rep Freq/A

Level 4/2 KV 5kHz Rep Freq/B

Surge Immunity

EN61000-4-5:1995

AC power line (live-neutral)

2 ohms

AC power line (live-earth)

12 ohms


DC power line (live-earth)


DC Power line (return-earth)

Signal lines 2 ohms

Class 4/2KV/B


Class 4/4KV/B


Class 4/500V/B


Class 4/500V/B


Indoor: 500V

Outdoor: 4KV/R

Table A-4

Electromagnetic Emissions Requirements (continued)

Country

Standard Requirements

Class: Up to 1 GHz

todd.book Page 6 Monday, March 16, 2009 2:47 PM

Advertising