Appendix 7: raw arc voltage, Cut out for cable – Tweco A80-A120 CutMaster User Manual

Page 100

Advertising
background image

CUTMASTER A80, A120

APPENDIX A-10 Manual 0-5119

APPENDIX 7: RAW ARC VOLTAGE

If raw arc voltage is necessary for the torch height control, the customer must supply an 18 AWG (1.0 mm

2

),

single pair, unshielded cable rated for 300V or greater. All work must be performed following applicable local

and national codes.

1. Disconnect the power from the power supply.

2. Remove the screws that attach the power supply cover to the chassis. Remove the cover.

3. Route the cable through the customer supplied strain relief at the rear of the power supply.

Art # A-10286

Cut out for cable

4. On the main board use insulated type 1/4-inch ring lug terminal ends to connect to –Vout1 (- polarity) and

WORK 1 (+ polarity).

!

WARNING

The raw arc voltage can exceed 350VDC !!!!

-V OUT 1

WORK 1

J10

-V OUT 1

WORK 1

Art # A-10287