04 fault indicator, Fault indicator -3 – Tweco A80-A120 CutMaster User Manual
Page 75

CUTMASTER A80, A120
Manual 0-5119
SERVICE
5-3
5.04 Fault Indicator
At initial power up, two lights will temporarily illuminate for 2-3 seconds to show the version of software used.
To determine the first digit, count the function indicators left to right, 1 through 5. To determine the second
digit count the pressure indicators, reading from bottom to top, 0 through 7. In the example below the Temp
indicator and 76 psi indicators are ON indicating the version would be 2.3.
A
+
PSI
BAR
MAX
MAX
MIN
MIN
!
1 2 3 4
Art# A-07988
MIN
MAX
0
1
2
3
4
5
6
7
5
When the
!
"Fault" indicator is ON or blinking it will be accompanied by one of the pressure indicator
lights depending on what the Fault is. The following table explains each of those Faults.
Pressure
Indicator
Fault
Max
Over Pressure
90
Internal Error
85
Shorted Torch
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
NOTE
Fault explanations are covered in the following tables.