CUTMASTER A80, A120

Manual 0-5119

OPERATION

4T-21

Mild Steel
120A
Air Plasma / Air Shield

Deflector

Standard Shield Cup

Maximum Life Shield Cup

Tip

Starter Cartridge

Electrode

9-8243

9-8218

9-8237

9-8233

9-8213

9-8232

Material

Thickness

Gas

Pressure

(Air)

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec. Speed

(GA)

(in)

inch

PSI

(torch lead

length)

Volts

(in)

(ipm)

(in)

(sec)

(in)

1/4

0.250

80 (25')

80 (50')

134

0.19

150

0.25

0.10

0.11

3/8

0.375

141

0.19

85

0.25

0.30

0.11

1/2

0.500

141

0.19

70

0.25

0.80

0.12

5/8

0.625

146

0.19

45

0.25

1.00

0.12

3/4

0.750

150

0.19

30

0.25

1.20

0.12

7/8

0.875

160

0.25

25

Edge Start

0.14

1

1.000

163

0.25

19

Edge Start

0.14

1-1/4

1.250

168

0.25

12

Edge Start

0.15

1-1/2

1.500

172

0.25

8

Edge Start

0.16

Material

Thickness

Gas Pressure

(Air)

Arc Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec. Speed

(mm)

Bar

(torch lead

length)

Volts

(mm)

(mm/min)

(mm)

(sec)

(mm)

6.0

5.5 (7.6 m)

5.5 (15.2 m)

133

4.8

3990

6.4

0.1

2.5

8.0

138

4.8

2950

6.4

0.2

2.7

10.0

141

4.8

2100

6.4

0.4

2.8

12.0

141

4.8

1860

6.4

0.6

2.9

15.0

145

4.8

1320

6.4

1.0

3.0

20.0

153

4.8

720

6.4

1.2

3.2

25.0

163

6.4

500

Edge Start

3.6

30.0

167

6.4

355

Edge Start

3.8

35.0

170

6.4

255

Edge Start

4.0

40.0

173

6.4

175

Edge Start

4.2

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.