Aluminum 120a air plasma / air shield – Tweco A80-A120 CutMaster User Manual

Page 55

Advertising
background image

CUTMASTER A80, A120

Manual 0-5119

OPERATION

4T-23

Aluminum
120A
Air Plasma / Air Shield

Deflector

Standard Shield Cup

Maximum Life Shield Cup

Tip

Starter Cartridge

Electrode

9-8243

9-8218

9-8237

9-8233

9-8213

9-8232

Material

Thickness

Gas Pressure

(Air)

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(GA) (in)

inch

PSI

(torch lead length)

Volts

(in)

(ipm)

(in)

(sec)

(in)

1/4

0.250

80 (25')

80 (50')

139

0.19

180

0.25

0.30

0.11

3/8

0.375

140

0.19

110

0.25

0.50

0.11

1/2

0.500

143

0.19

75

0.25

0.80

0.11

5/8

0.625

156

0.25

50

0.30

1.00

0.12

3/4

0.750

161

0.25

34

Edge Start

0.13

1

1.000

167

0.25

23

Edge Start

0.14

Material

Thickness

Gas Pressure

(Air)

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(mm)

Bar

(torch lead length)

Volts

(mm)

(mm/min)

(mm)

(sec)

(mm)

6

5.5 (7.6 m)

5.5 (15.2 m)

139

4.8

4770

6.4

0.2

2.8

8

140

4.8

3650

6.4

0.2

2.8

10

140

4.8

2660

6.4

0.5

2.8

12

142

4.8

2100

6.4

0.8

2.8

15

152

6.4

1445

7.6

1.2

3.0

20

162

6.4

820

Edge Start

3.4

25

167

6.4

600

Edge Start

3.4

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.

Advertising