Stainless steel 100a air plasma / air shield – Tweco A80-A120 CutMaster User Manual

Page 51

Advertising
background image

CUTMASTER A80, A120

Manual 0-5119

OPERATION

4T-19

Stainless Steel
100A
Air Plasma / Air Shield

Deflector

Standard Shield Cup

Maximum Life Shield Cup

Tip

Starter Cartridge

Electrode

9-8243

9-8218

9-8237

9-8212

9-8213

9-8232

Material

Thickness

Gas Pressure

(Air)

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(GA) (in)

inch

PSI

(torch lead length)

Volts

(in)

(ipm)

(in)

(sec)

(in)

1/4

0.250

75 (25')

75 (50')

102

0.16

100

0.18

0.00

0.09

3/8

0.375

106

0.16

65

0.18

0.10

0.10

1/2

0.500

109

0.16

45

0.18

0.30

0.10

5/8

0.625

123

0.19

20

0.23

2.00

0.11

3/4

0.750

128

0.19

15

Edge Start

0.12

1

1.000

135

0.19

10

Edge Start

0.13

Material

Thickness

Gas Pressure

(Air)

Arc Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce Delay

Kerf Width

@ Rec.

Speed

(mm)

Bar

(torch lead length)

Volts

(mm)

(mm/min)

(mm)

(sec)

(mm)

6

5.2 (7.6 m)

5.2 (15.2 m)

102

4.1

2630

4.6

0.00

2.3

8

104

4.1

2080

4.6

0.10

2.4

10

106

4.1

1575

4.6

0.20

2.4

12

108

4.1

1255

4.6

0.30

2.4

15

119

4.6

685

5.7

2.00

2.7

20

129

4.8

360

Edge Start

3.1

25

135

4.8

260

Edge Start

3.2

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.