Stainless steel 120a air plasma / air shield – Tweco A80-A120 CutMaster User Manual

Page 54

Advertising
background image

CUTMASTER A80, A120

OPERATION Manual 0-5119

4T-22

Stainless Steel
120A
Air Plasma / Air Shield

Deflector

Standard Shield Cup

Maximum Life Shield Cup

Tip

Starter Cartridge

Electrode

9-8243

9-8218

9-8237

9-8233

9-8213

9-8232

Material

Thickness

Gas Pressure

(Air)

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(GA) (in)

inch

PSI

(torch lead length)

Volts

(in)

(ipm)

(in)

(sec)

(in)

1/4

0.250

80 (25')

80 (50')

133

0.19

180

0.25

0.20

0.10

3/8

0.375

136

0.19

100

0.25

0.40

0.11

1/2

0.500

140

0.19

60

0.25

0.80

0.11

5/8

0.625

152

0.25

40

0.30

1.20

0.13

3/4

0.750

154

0.25

26

Edge Start

0.14

1

1.000

159

0.25

16

Edge Start

0.14

1-1/4

1.250

167

0.25

8

Edge Start

0.14

Material

Thickness

Gas Pressure (Air) Arc Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce Delay

Kerf Width

@ Rec.

Speed

(mm)

Bar

(torch lead length)

Volts

(mm)

(mm/min)

(mm)

(sec)

(mm)

6

5.5 (7.6 m)

5.5 (15.2 m)

133

4.8

4800

6.4

0.2

2.6

8

135

4.8

3520

6.4

0.2

2.7

10

137

4.8

2390

6.4

0.5

2.8

12

139

4.8

1750

6.4

0.8

2.9

15

149

6.4

1160

7.6

1.2

3.4

20

155

6.4

625

Edge Start

3.6

25

159

6.4

425

Edge Start

3.6

30

165

6.4

260

Edge Start

3.6

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.

Advertising