Mild steel 100a air plasma / air shield – Tweco A80-A120 CutMaster User Manual

Page 65

Advertising
background image

CUTMASTER A80, A120

Manual 0-5119

OPERATION

4T-33

Mild Steel
100A
Air Plasma / Air Shield

Shield Cap

Maximum Life Shield Cup

Tip

Starter Cartridge

Electrode

9-8239

9-8237

9-8233

9-8213

9-8232

Material

Thickness

Gas Pressure

(Air)

Arc Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(GA) (in)

inch

PSI

(torch lead length)

Volts

(in)

(ipm)

(in)

(sec)

(in)

1/4

0.250

75 (25')

75 (50')

114

0.16

85

0.18

0.00

0.08

3/8

0.375

112

0.16

70

0.18

0.20

0.09

1/2

0.500

115

0.16

40

0.18

0.30

0.10

5/8

0.625

123

0.16

30

0.18

0.40

0.10

3/4

0.750

127

0.16

20

0.18

0.80

0.11

1

1.000

133

0.16

12

Edge Start

0.12

1-1/4

1.250

135

0.16

8

Edge Start

0.12

Material

Thickness

Gas Pressure

(Air)

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(mm)

Bar

(torch lead length)

Volts

(mm)

(mm/min)

(mm)

(sec)

(mm)

6

5.2 (7.6 m)

5.2 (15.2 m)

114

4.1

2210

4.6

0.00

2.0

8

113

4.1

1960

4.6

0.10

2.2

10

112

4.1

1665

4.6

0.20

2.3

12

114

4.1

1185

4.6

0.30

2.4

15

121

4.1

830

4.6

0.40

2.5

20

128

4.1

475

5.0

0.80

2.8

25

133

4.1

315

Edge Start

2.9

30

134

4.1

230

Edge Start

3.1

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.

Advertising