Aluminum 60a air plasma / air shield – Tweco A80-A120 CutMaster User Manual

Page 61

Advertising
background image

CUTMASTER A80, A120

Manual 0-5119

OPERATION

4T-29

Aluminum
60A
Air Plasma / Air Shield

Shield Cap

Maximum Life Shield Cup

Tip

Starter Cartridge

Electrode

9-8238

9-8237

9-8210

9-8213

9-8232

Material

Thickness

Gas Pressure

(Air)

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(GA) (in)

inch

PSI

(torch lead length)

Volts

(in)

(ipm)

(in)

(sec)

(in)

16

0.064

85 (25')

90 (50')

118

0.13

350

0.20

0.00

0.07

14

0.079

118

0.13

350

0.20

0.10

0.08

11

0.120

123

0.13

275

0.20

0.10

0.08

3/16

0.188

125

0.13

140

0.20

0.20

0.08

1/4

0.250

132

0.13

80

0.20

0.30

0.08

3/8

0.375

135

0.13

45

0.20

0.50

0.08

1/2

0.500

140

0.13

26

0.20

0.80

0.08

5/8

0.625

148

0.19

18

Edge start

0.10

3/4

0.750

155

0.19

12

Edge start

0.11

Material

Thickness

Gas Pressure

(Air)

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf Width

@ Rec.

Speed

(mm)

Bar

(torch lead length)

Volts

(mm)

(mm/min)

(mm)

(sec)

(mm)

1

5.9 (7.6 m)

6.2 (15.2 m)

118

6.4

8890

6.4

0.00

2

2

118

6.4

8890

6.4

0.10

2.0

3

123

6.4

7070

6.4

0.10

2.1

4

124

6.4

5095

6.4

0.20

2.0

5

126

6.4

3335

6.4

0.20

2.0

6

130

6.4

2370

6.4

0.30

2.0

8

134

6.4

1570

6.4

0.40

2.0

10

136

6.4

1070

6.4

0.60

2.0

12

139

6.4

765

6.4

0.70

2.0

15

146

4.8

515

Edge start

2.4

20

157

4.8

260

Edge start

2.7

BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.