Aluminum 100a air plasma / air shield – Tweco A80-A120 CutMaster User Manual
Page 67
CUTMASTER A80, A120
Manual 0-5119
OPERATION
4T-35
Aluminum
100A
Air Plasma / Air Shield
Shield Cap
Maximum Life Shield Cup
Tip
Starter Cartridge
Electrode
9-8239
9-8237
9-8212
9-8213
9-8232
Material
Thickness
Gas Pressure
(Air)
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf Width
@ Rec.
Speed
(GA) (in)
inch
PSI
(torch lead length)
Volts
(in)
(ipm)
(in)
(sec)
(in)
1/4
0.250
75 (25')
75 (50')
121
0.18
110
0.19
0.00
0.10
3/8
0.375
129
0.18
60
0.19
0.20
0.10
1/2
0.500
135
0.18
45
0.19
0.30
0.11
5/8
0.625
133
0.18
32
0.19
0.60
0.11
3/4
0.750
138
0.18
25
0.19
2.00
0.11
1
1.000
143
0.18
15
Edge Start
0.14
Material
Thickness
Gas Pressure
(Air)
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf Width
@ Rec.
Speed
(mm)
Bar
(torch lead length)
Volts
(mm)
(mm/min)
(mm)
(sec)
(mm)
6
5.2 (7.6 m)
5.2 (15.2 m)
120
4.6
2920
4.8
0.00
2.5
8
125
4.6
2135
4.8
0.10
2.5
10
130
4.6
1470
4.8
0.20
2.6
12
134
4.6
1230
4.8
0.30
2.7
15
134
4.6
905
4.8
0.60
2.9
20
139
4.6
595
6.0
2.00
3.0
25
143
4.6
395
Edge Start
3.6
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.