Pak 200 specifications – Tweco Pak 200 User Manual

Page 20

Advertising
background image

SPECIFICATIONS 2-2 Manual

0-5057

PAK 200

SPECIFICATIONS

2.06 Power Supply Specifi cations & Electrical Requirements

PAK 200 Power Supply Specifi cations

Max OCV (U

0

)

380 VDC

Max Output Current

200 Amps

Output Voltage

160 VDC

Duty Cycle Rating

100% @ 200A @ 160V (32 kW)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.70 @ 200 ADC Output

Cooling

Forced Air (Class F)

Table 2-2: PAK 200 Power Supply Specifi cations

PAK-200 Power Supply

Input

Power Input

Current

Suggested Sizes (See NOTE)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

60

47

130

160

#2

2

230

60

49

125

150

#2

2

400

50

54

77

100

#4

1

460

60

59

75

90

#4

1

Line Voltages with Suggested Circuit Protection and Wire Sizes

NOTE: Based on National Electric Code and Canadian Electrical Code

1

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW

2

Extra Hard Usage Type G, G-GC, W

Table 2-3: PAK 200 Power Supply

CAUTION

Fuse and wire sizes are for reference only. The installation must conform to national and local codes

for the type and method of wire being used.

Advertising