Pak 200 specifications – Tweco Pak 200 User Manual
Page 20
SPECIFICATIONS 2-2 Manual
0-5057
PAK 200
SPECIFICATIONS
2.06 Power Supply Specifi cations & Electrical Requirements
PAK 200 Power Supply Specifi cations
Max OCV (U
0
)
380 VDC
Max Output Current
200 Amps
Output Voltage
160 VDC
Duty Cycle Rating
100% @ 200A @ 160V (32 kW)
Operating range
14°F to 122°F (-10°C to + 50°C)
Power Factor
0.70 @ 200 ADC Output
Cooling
Forced Air (Class F)
Table 2-2: PAK 200 Power Supply Specifi cations
PAK-200 Power Supply
Input
Power Input
Current
Suggested Sizes (See NOTE)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
208
60
47
130
160
#2
2
230
60
49
125
150
#2
2
400
50
54
77
100
#4
1
460
60
59
75
90
#4
1
Line Voltages with Suggested Circuit Protection and Wire Sizes
NOTE: Based on National Electric Code and Canadian Electrical Code
1
Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW
2
Extra Hard Usage Type G, G-GC, W
Table 2-3: PAK 200 Power Supply
CAUTION
Fuse and wire sizes are for reference only. The installation must conform to national and local codes
for the type and method of wire being used.