09 set switches for command-control module, Pak 200 installation – Tweco Pak 200 User Manual

Page 36

Advertising
background image

INSTALLATION 3-10

Manual

0-5057

PAK 200

INSTALLATION

3.09 Set Switches for Command-Control Module

Remove the power supply right side. Set switches on the CCM (Command-Control Module) per the illustrations.
Switch settings and connection details are provided in the Appendix.

CAUTION

Printed circuit boards in the Command - Control Module are static - sensitive. Discharge any built-up

static charges in you body or surroundings before touching the printed circuit boards.

SW1

SW3

SW4

SW5

SW8

3

4

1

2

3

4

1

2

1

2

1

2

1

2

1

2

SW-1-1: Auto Pilot Restart. 1 = ON = Auto Pilot Function enabled. (Factory default setting).
1 = OFF = Auto Pilot Function disabled
SW-1-2: Pilot Delay 2 = OFF, 3 = OFF, 4 = OFF: 0 Seconds (Factory default setting).
SW-1-3: Pilot Delay 2 = ON, 3 = OFF, 4 = OFF: 0.1 Seconds
SW-1-4: Pilot Delay 2 = OFF, 3 = ON, 4 = OFF: 0.2 Seconds
2 = ON, 3 = ON, 4 = OFF: 0.4 Seconds
2 = OFF, 3 = OFF, 4 = ON: 0.8 Seconds
2 = ON, 3 = OFF, 4 = ON: 1.0 Seconds
2 = OFF, 3 = ON, 4 = ON: 1.5 Seconds
2 = ON, 3 = ON, 4 = ON: 2.0 Seconds

SW-4: Postflow Time 1 = OFF, 2 = OFF: 10 Seconds (Factory default setting).
1 = ON, 2 = OFF: 20 Seconds
1 = OFF, 2 = ON: 5 Seconds
1 = ON, 2 = ON: 0 Seconds

SW-5-1: Tip Saver

SW5-1 not used, Tip Saver always on.


SW-5-2: Off Plate

Reserved for Factory use.

SW 8-1: Pilot Time 1 = OFF = Short (85 ms.)

1 = ON = Long (3 s.) (Factory default setting).

O
N

O
N

Active only when
SW-1-1 is set to O N.

Art # A-08379_AC

Future Use

SW-3: Gas Preflow Time 1 = OFF, 2 = OFF: 2 seconds

(Factory default setting).

1 = ON, 2 = OFF: 4 seconds

1 = OFF, 2 = ON: 6 seconds

1 = ON, 2 = ON: 8 seconds

SW 8-2: Remote Current 2 = OFF = Front panel current control (Factory default setting).

2 = ON = (Remote Analog Current Control) See also SW11

SW 8-3, SW8-4:

Reserved for Factory use.

Figure 3-10: Set Switches 1