5.03 Arc Starter Service

Arc Starter Service Chart

Symptom

Cause

Check

Remedy

No Pilot Ignition:

Spark in Arc Starter,

but not ignition

Coolant has become con-
ductive

Use conductivity meter

Flush system, replace cool-
ant.

Pilot return wire not con-
nected

Visual inspection

Connect wire.

Spark gap set too close

Check with feeler gauge

Set to 0.063” ±0.002”

High frequency cap (CA)
Possibly open

Use capacitance meter

Reconnect or replace.

Broken or missing ferrites

Visual inspection

Replace.

Short across in indicator
(L1)

Visual inspection

Remove short, increase
coil gaps.

Spark gap bus caps (C1,
C2, C3) broken or defective

Capacitance meter

Replace.

Negative supply not con-
nected correctly

Visual inspection

Reconnect.

No Pilot Ignition:

No Spark in Arc

Starter

Spark gap set too large

Check with feeler gauge

Set to 0.063” ±0.002”

Faulty transformer

Resistance measurement

Replace.

No 120V supply

Check input voltage at EMI
fi lter

Make connections; replace
harness.

No / loose connection to
spark gap

Visual inspection

Reconnect.

Faulty EMI fi lter

Voltage / Resistor mea-
surement

Replace.

No cooling or

insuffi cient cooling:

Leaks coolant

Loose fi tting(s)

Visual inspection

Tighten fi ttings.

Failure to braze joints (L1)

Visual inspection

Replace HF Coil

Damaged or punctured
coolant line(s)

Visual inspection

Replace coolant line(s).

No cooling or

insuffi cient cooling:

No Coolant Flow

Supply & return hoses
reversed

Visual inspection 0 color-
coded connections

Match coolant connection
colors to ark starter fi ttings
colors.

Blockage in coil or supply
return hoses

Loosen fi tting slightly and
check for coolant fl ow

Flush system.

Erratic System

Behavior

(EMI Interference)

Shield Drain / Torch lead in-
ner shield connector miss-
ing or loose

Visual inspection of lead
attachment to Arc Starter

Reconnect / tighten lead
connections.

Missing or loose ground
connection

Visual inspection of ground
wire to Arc Starter

Make or tighten connec-
tions to good ground.

Cap C5 not connected, pen
or loose

Visual inspection capacitor
measurement

Replace PCB.

Table 5-3: Arc Starter Service Chart