MAINTENANCE

5.02 Coolant Replacement Procedure

Replace coolant as follows:

1. Disconnect the system from MAINTENANCE input power. At the bottom of the coolant tank, disconnect the

coolant line fi tting and collect coolant in a disposable container.

2. Connect the system to MAINTENANCE input power and turn it ON to allow the pump to empty the tank. The

pump will run approximately for 20 seconds before the fl ow switch causes an interlock. This procedure may
be repeated a few times until the tank is completely empty.

3. Connect the coolant line fi tting and fi ll the tank with fresh coolant until the right level is reached.

RETURN

SUPPLY

RETURN

SUPPLY

Art # A-04803

COOLANT

Fill Range

Coolant Tank

Figure 5-2: Coolant Fill

4. Turn system ON, let it run for a few minutes and check coolant level, refi ll if necessary.