Section 5: maintenance, 01 maintenance schedule, 01 coolant filter cleaning procedure – Tweco Pak 200 User Manual

Page 55: Maintenance pak 200

Advertising
background image

Manual 0-5057

5-1

MAINTENANCE

MAINTENANCE

PAK 200

SECTION 5:

MAINTENANCE

5.01 Maintenance

Schedule

Perform the following checks periodically to ensure proper system performance.

Power Supply Maintenance Schedule

Daily

Check coolant level; add coolant as needed.

Check gas hose connections and pressures.

Check cooling fan; clean as needed.

Monthly

Check cooling fan and radiator; clean as needed.

Check gas hoses for cracks, leaks, or abrasion.
Replace as needed.

Check all electrical connections for cracks or
abrasion. Replace as needed.

Six Months

Replace coolant fi lter.

Clean coolant tank.

Vacuum out any dust buildup inside power
supply.

Table 5-1: Power Supply Maintenance Schedule

5.01 Coolant Filter Cleaning Procedure

Periodic cleaning of the coolant fi lter ensures maximum coolant fl ow effi ciency. Poor coolant fl ow causes inef-
fi cient torch parts cooling with consequent faster consumable wear.

Clean the coolant fi lter as follows:

1. Disconnect system from maintenance input power.

2. Unscrew and remove the fi lter bowl by hand. Be sure to keep the O-ring.

3. Remove and clean the fi lter. Re-install the bowl, tightening it by hand. Be sure the O-ring is in place.

4. Turn the system ON and check for leaks.

Advertising