09 gas requirements, 10 gas applications, Specifications pak 200 – Tweco Pak 200 User Manual

Page 23

Advertising
background image

Manual 0-5057

2-5

SPECIFICATIONS

SPECIFICATIONS

PAK 200

2.09 Gas

Requirements

The customer will provide all gases and pressure regulators. Gases must be of high quality. Pressure regulators
shall be equipped with stainless-steel diaphragms and installed as close as possible to the Gas Console. Specify Dual
Stage Stainless diaphragm regulators for hi-pressure cylinders (> 400 inlet psi) (example: Victor VTS-450-D-500,)
Single stage Station-stainless diaphragm regulator for low pressure (< 350 inlet psi) liquid or bulk tank supply
application (example Victor # LC-350DR).

MATERIAL

MILD STEEL

STAINLESS STEEL

ALUMINUM

OPERATION

GAS TYPE

GAS TYPE

GAS TYPE

PLASMA

SHIELD

PLASMA

SHIELD

PLASMA

SHIELD

35-200 A Cut

Air

Air

H35

N2

H35

N2

Table 2-6: Gas Requirements

PAK-200 Power Supply: Gas Pressures, Flows, and Quality Requirements

Gas

Quality

Minimum Pressure

Flow

N

2

(Nitrogen)

99.5% Purity

(Liquid recommended)

<1000 ppm O

2

, <32 ppm H

2

O)

80 psi

5.5 bar / 827 kPa

350 scfh (165 l/min)

Compressed

Air

Clean, Dry,

Free of Oil (see Note 1)

90 psi

6.2 bar / 621 kPa

450 scfh (212 1/min)

H35 (Argon-Hydrogen)

H35 = 35% Hydrogen,

65% Argon

99.995% Purity

(gas recommended)

90 psi

6.2 bar / 827 kPa

100 scfh (47 1/min)

H

2

O (Water)

See Note 2

50 psi (3.5 bar)

10 gph (38 lph)

Note 1: The air source must be adequately fi ltered to remove all oil or grease. Oil or grease contamination from
compressed or bottled air can cause fi res in conjunction with oxygen.

For fi ltering, a coalescing fi lter able to fi lter to 0.01 microns should be placed as close as possible to the gas inlets
on the Gas Control Module.

Note 2: The tap water source does not need to be deionized, but in water systems with extremely high mineral
content a water softener is recommended. Tap water with high levels of particulate matter must be fi ltered.

Table 2-7: Gas Pressures, Flows, & Quality Requirements

2.10 Gas

Applications

The customer will provide all gases and pressure regulators. Gases must be of high quality. Pressure regulators
shall be equipped with stainless-steel diaphragms and installed as close as possible to the Gas Console.

MATERIAL

MILD STEEL

STAINLESS STEEL

ALUMINUM

OPERATION

GAS TYPE

GAS TYPE

GAS TYPE

PLASMA

SHIELD

PLASMA

SHIELD

PLASMA

SHIELD

35-200 A Cut

Air

Air

H35

N

2

H35

N

2

Table 2-8: Gas Applications

Advertising