08 duty cycle, 09 duty cycle, Duty cycle -3 – Tweco ArcMaster 401MST User Manual

Page 27: Arcmaster 401mst power source, Welding current (amps), Duty cycle (percentage), Safe operating region, 3 phase 1 phase, Figure 2-1: duty cycle

Advertising
background image

ARCMASTER 401MST POWER SOURCE

Manual 0-5287

2-3 INTRODUCTION

2.08 Duty Cycle

The rated duty cycle of a Welding Power Source, is a statement of the time it may be operated at its rated weld-

ing current output without exceeding the temperature limits of the insulation of the component parts. To explain

the 10 minute duty cycle period the following example is used. Suppose a Welding Power Source is designed to

operate at a 40% duty cycle, 170 amperes at 26.8 volts. This means that it has been designed and built to provide

the rated amperage (170A) for 4 minutes, i.e. arc welding time, out of every 10 minute period (40% of 10 minutes

is 4 minutes). During the other 6 minutes of the 10 minute period the Welding Power Source must idle and be

allowed to cool. The thermal cut out will operate if the duty cycle is exceeded.

Welding Current (AMPS)

Art # A-12450

0

10

20

30

40

50

60

70

80

90

100

0

25

50

75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500

Duty Cycle (PERCENTAGE)

3 phase

1 phase

SAFE OPERATING REGION

Figure 2-1: Duty Cycle

Advertising