14 special function, Special function -22, Arcmaster 401mst power source – Tweco ArcMaster 401MST User Manual

Page 52

Advertising
background image

ARCMASTER 401MST POWER SOURCE

INSTALLATION, OPERATION AND SETUP

3-22

Manual 0-5287

3.14 Special Function

Encoder Control Process Selection Button

Remote Control

Contactor Control

Amphenol Selector

Parameter Selection

Button

Art # A-12458_AB

Figure 3-11

Gouging

In Stick mode hold the Process Selection Button for 2 seconds and the LED will blink indicating Gouging

mode is enabled.

Lock/ Unlock User Interface (UI)

UI Lock Function can be enabled or disabled by pressing Encoder Control for 5 seconds.

NOTE

The function lock setting is saved! If the machine is switched off with the function lock activated, the

control panel is still locked when the machine is switched back on.

LED Test

Press Amphenol Selector or Parameter Selection Button for 2 seconds to start LED test. The test will last for

about 5 seconds. During the test all LEDs are lit.

Enable Calibration in MIG Mode

In MIG mode, the adjustment to output voltage can be enabled or disabled as below:
1. Press Contactor Control and Process Selection Button at the same time for 2 seconds.
2. Rotate Encoder Control to select CAL ON/OFF.

2a. Adjust the output voltage with the potentiometer on Control PCB 5 by +/- 5% (refer to Figure 3-3).

3. Press Encoder Button Encoder Control to save the setting.

Display Software Version

Press Remote Control and Contactor Control buttons at the same time for 2 seconds and it will display the

software version of User Interface (UI), master and process.

Master Reset

!

WARNING

All personal settings will be lost!

The 401MST can have master reset. All the jobs saved will be deleted and all parameters will be set back to

factory setting. This function is accessed by pressing Parameter Selection Button and Remote Control Button

at the same time for 2 seconds.

Advertising