ARCMASTER 401MST POWER SOURCE

Manual 0-5287

3-9

INSTALLATION, OPERATION AND SETUP

9 Contactor Control

Local Control

Remote Control

Contactor Control either enables the weld output or assigns this function to a remote device. Refer to 3.14

Special Function for more info.

10 Positive Welding Terminal

Welding current flows from the Power Source via heavy duty Dinse type terminal. It is essential, however, that

the male plug is inserted and turned securely to achieve a sound electrical connection.

11 Negative Welding Terminal

Welding current flows from the Power Source via heavy duty Dinse type terminal. It is essential, however, that

the male plug is inserted and turned securely to achieve a sound electrical connection.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused in

the terminal.

12 Intelligent Fan Control

The intelligent cooling system is designed to reduce dust and foreign material build-up, while providing optimum

cooling. Fan speed reduces approximately 30 seconds after machine is turned on and increases when internal

components reaches operating temperature.

13 14 Pin Remote Control Socket

The 14 pin Remote Control Socket is used to connect Remote Control devices or wire feeders that use a

14 pin connection to the welding Power Source. To make connections, align keyway, insert plug, and rotate

threaded collar fully clockwise.

Pin

Function

Description

A

24VAC

B

Contactor

Connect A&B -> contactor enable

C

+10VDC Remote Ctrl (Max)

10 VDC for remote potentiometer supply

D

Remote Ctrl return/common (Min) Common

E

Remote Demand/Wiper

Remote control demand signal. Voltage: 0<=Vin<=10V

F

Amperage output signal

Output current signal. 1Vout/100Aout

G

24/115VAC Common

24/115VAC common and chassis ground

H

Output voltage signal

Voltage feedback. 1Vout/10Varc

I

115VAC

J

Contactor Enable

Connect I&J --> contactor enable

K

Chassis ground

M

Arc established

Relay contact between M & N will close while welding is active

N

Arc established

Table 3-2 14 Pin Interconnection Control Plug Configuration, 401MST