ARCMASTER 401MST POWER SOURCE

Manual 0-5287

5-3 POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS

Code

Error

Cause

Possible Remedy

E08-11

V/I Acquisition

Voltage/current measuring

systems faulty

Take to an accredited Tweco Service

Center for repair.

E08-13

CAN Identification

Unknown device connected

Check connected devices and CAN

connections

E09

Output Voltage

Voltage measuring system

faulty.

Torch is touching work piece

Take to an accredited Tweco Service

Center for repair.

Raise Torch from contact with work

piece.

E12

Power Section

Power section start-up faulty.

Torch is touching work piece

Take to an accredited Tweco Service

Center for repair.

Raise Torch from contact with work

piece.

E13

Temperature Sensor

Temperature sensor not ready

for operation

Take to an accredited Tweco Service

Center for repair.

E14

Supply Voltage

Internal supply voltage too low Check mains voltages

E15

Current Detection

Error during current measure-

ment

Take to an accredited Tweco Service

Center for repair.

E18

Overload Protection

Safety switch device to protect

elec trical components

Take to an accredited Tweco Service

Center for repair.

E22

Mains Undervoltage

Mains voltage on power unit is

too low

Check mains voltages

E25

Idle Generator

Idle generator faulty

Take to an accredited Tweco Service

Center for repair.

E30

Error Configuration

Faulty or wrong pc-board,

wrong software system

installed

Take to an accredited Tweco Service

Center for repair.

E31

Communications Fault

CAN bus communication

faulty

Switch the equipment off and on

again

E32

FPGA

FPGA faulty

Take to an accredited Tweco Service

Center for repair.

E33

Power Section

Power module not symmetri-

cal

Take to an accredited Tweco Service

Center for repair.

E34

Fans

Fan current faulty

Take to an accredited Tweco Service

Center for repair.

E39

Protective Earth Conductor

Monitoring

Fault current to protective

earth con ductor

Connect the welding earth lead

E40

Voltage detection

Voltage measurement faulty at

the socket

Take to an accredited Tweco Service

Center for repair.

E47

Undefined Mains

Mains voltage between per-

mitted ranges

Check mains

Table 5-2 Power Source Error Messages