Arcmaster 401mst power source – Tweco ArcMaster 401MST User Manual

Page 40

Advertising
background image

ARCMASTER 401MST POWER SOURCE

INSTALLATION, OPERATION AND SETUP

3-10

Manual 0-5287

14 19 Pin Remote Control Socket

The 19 pin Remote Control Socket is used to connect Remote Control devices or wire feeders that use a

19 pin connection to the welding Power Source. To make connections, align keyway, insert plug, and rotate

threaded collar fully clockwise.

Pin

Function

Description

A

+16VDC contactor

16 VDC supply voltage for contactor. Connect A & B for contactor enable

B

Contactor in

Contactor input. Connect A & B for contactor enable

C

Volt Meter

Voltage feedback. 1Vout/10Varc

D

24VAC

E

115VAC

F

24/115VAC neutral

VAC neutral

G

Ground

H

+10VDC remote ctrl

10 VDC for remote potentiometer supply

J

Remote Input

0<=Vin<=10V

K

Remote ctrl ground/common Also control circuit common

L

BF04 ground / common

M

12VDC arc established

+12 VDC while welding active, otherwise off

N

Ground / common

P

24VAC

R

N VAC

24/115VAC neutral and chassis ground

S

CAN_high

CAN bus; positive signal

T

CAN_low

CAN bus; negative signal

U

Amp Meter

Current feedback. 1Vout/100AAout

V

+24VDC

+ 24VDC CAN supply

Table 3-3 19 Pin Interconnection Control Plug Configuration, 401MST

15 ON/OFF Switch

This switch connects the Primary supply voltage to the inverter when in the ON position. This enables the

Power Supply.

!

WARNING

When the welder is connected to the Primary supply voltage, the internal electrical components may

be at 500V potential with respect to earth.

16 Input Cable

The input cable connects the Primary supply voltage to the equipment.

17. 2.5A Circuit Breaker

2.5A Circuit Breaker is for the 115 VAC auxiliary power connected to 14 pin or 19 pin remote control socket.

18. 10A Circuit Breaker

10A Circuit Breaker is for the 24 VAC auxiliary power connected to 14 pin or 19 pin remote control socket.

Advertising