02 power source status messages, 03 error messages, Power source status messages -2 – Tweco ArcMaster 401MST User Manual

Page 74: Error messages -2, Arcmaster 401mst power source

Advertising
background image

ARCMASTER 401MST POWER SOURCE

POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS 5-2 Manual 0-5287

5.02 Power Source Status Messages

An error code is displayed in the digital displays in the event of a malfunction. You can switch over between error

code and sub-error (sub code) in the digital displays by pressing Process Selection Button.
After the message has been displayed, the machine will only function to a limited extent; the error must be cor-

rected as quickly as possible.
The status message can be deleted by pressing Encoder Control.

Code

Note

Cause

Possible Remedy

H08

Short-circuit

Short-circuit in the output circuit

Eliminate the short-circuit (pick up

electrode holder, ...)

H30

Configuration

Component group recognition faulty Take to an accredited Tweco Service

Center for repair.

H31

Communication

CAN bus communication faulty

Check connected devices and CAN

connections

Table 5-1 Power Source Status Messages

5.03 Error Messages

!

WARNING

There are extremely dangerous voltage and power levels present inside this Inverter Power Source.

Do not attempt to open or repair unless you are an accredited Tweco Service Provider. Disconnect the

Welding Power Source from the Mains Supply Voltage before disassembling.

An error code is displayed in the digital displays in the event of a malfunction. You can switch over between error

code and sub-error (sub code) in the digital displays by pressing any button. As long as there is an error code

on display welding is not possible.

Code

Error

Cause

Possible Remedy

E01

Excessive Temperature

Duty cycle exceeded

Allow switched-on machine to cool

down for a few minutes

Dust filter contaminated

Replace dust filter

E02

Overvoltage

Mains voltage too high

Check mains voltage

E06

Overvoltage Secondary

Initial voltage too high

Take to an accredited Tweco Service

Center for repair.

E07

EEPROM

Communication with EEPROM

defec tive

Switch machine off and on and

execute Master reset. If error code

returns take to and accredited Tweco

Service Center for repair.

E08-1

Excess Wirefeeder Voltage

Wirefeeder voltage too high

Take to an accredited Tweco Service

Center for repair.

E08-2

Wirefeeder Motor

Error in Wirefeeder Motor

Take to an accredited Tweco Service

Center for repair.

E08-3

Overcurrent on Wirefeeder

Wirefeeder current continu-

ously too high

Reduce motor load

E08-10

Torch Connection

Torch/torch connection error

Check torch and torch connection.

Switch the equipment off and on

again

Advertising