6.10.F–Hard Power and Remote Unlock (91-) with Forced/Propped Door (DM-)

Installation

1. ElectroLynx

®

System Wiring Instructions (refer to Fig. 1 and Fig. 4)

a. Look for the mating part on ASSA ABLOY doors & frames. Then plug in all connectors as shown in

Fig. 4 during product installation

b. Hard wire forced/propped, hard power and/or remote unlock (REX), as shown

2. Non-ElectroLynx

®

System Wiring Instructions (refer to Fig. 1 and Fig. 4map)

a. Cut the 8-pin connector off the Remote Power/Unlock harness and hard wire to non-ElectroLynx

®

door harness. Remote power requires three conductors and remote unlock requires two conductors.

b. Hard wire door harness to power transfer device

c. Hard wire forced/propped, hard power and/or remote unlock (REX), as shown