IN100 Mortise Lock

14 Configuring RX Switch Handing

1. Each lever handle has a sensor installed but only the inside lever is

utilized for RX sensing.

2. To properly configure the RX functionality, connect the terminals as

indicated below:

RH or RHRB door handing (blue to blue)

LH or LHRB door handing (yellow to blue)
3. Note: Factory default is blue to blue (right hand lock).

IMPORTANT: grasp each connector firmly before separating.

Do not pull wires apart.

Wire harness

Wire harness

DPS

Lock
body
wiring

15 Battery Housing Wiring

1. Connect the outside reader ribbon cable to the top of the

battery housing (See Fig.15B for detail).
2. Connect the DPS wire to the 3-wire header at the lower

left corner of the PCB.

3. Connect the lock body harness to the 5-wire header at

the lower right corner of the PCB.

IMPORTANT: Confirm the correct connector orientation

prior to assembly. Do not force connectors
4. Note: If the HID wire harness must be twisted to connect to

the battery housing the HID reader has been installed upside

down. Turn the HID reader right side up and reinstall, then

connect.

Lock
body
wiring

DPS

Fig. 15A

Fig. 15B

Inside of Door

Fig. 14