IN100 Mortise Lock

3 Lock Self Test LED Indication

After replacing the battery, a Power On Self Test (POST) is performed. The result is indicated

using a series of red and green LED flashes as is described by the figure below:

One red, one green flash

(1 second each)

One red flash followed by 16 red or

green flashes (.5 s each)

Fig. Lock POST LED indication

The first flash is always red. If the POST fails, the color of the 16 trailing flashes indicate the

status of each individual test as described by the following table:

Blink

Meaning if Red

Code in Event Log

2

Main board firmware corrupt

0x0001

3

Override list corrupt

0x0002

4

Production data corrupt

0x0004

5

Security data corrupt

0x0008

6

Configuration data corrupt

0x0010

7

Battery power low

0x0020

8

RFID reader circuit error

0x0040

9

Voltage regulator error

0x0080

10

Card detection circuit error

0x0100

11

Secure area communication error

0x0200

12

Secure area memory corrupt

0x0400

13

Secure area sensor or motor error

0x0800

14

Radio modem communication error

0x1000

15

Radio modem memory corrupt

0x2000

16

Radio modem configuration error

0x4000

17

Radio modem RF circuit error

0x8000

NOTE: If the battery is not accepted as new after a power on reset, no POST is performed.

Instead, the 10 quick red flashes used to indicate Error in lock is shown.