H. al- 80 series exit device installation – SARGENT AL - Alarmed Exit User Manual

Page 4

Advertising
background image

4

H. AL- 80 Series Exit Device Installation

Finish mounting exit device per instruction sheet provided

Supplied with the 546 kit are two types of rail mounting brackets (standard & flush mount)

Select appropriate mounting bracket according to rail end cap type being installed

End caps stamped SARGENT are standard and end caps stamped SARGENT 80 are flush mount

Remove nut on mounting bracket, place lug from green wire on 546 harness on to center screw on

mounting bracket, then re-install nut and tighten

Plug rail connector(s) into raceway connector(s). Then feed through 1" hole in door

Install rail mounting bracket with two screws supplied. Install rail end cap

To ensure trouble free operation, check that the push rail can be fully depressed.

On vertical rod exit devices, adjust rods and check that the latch bolts do not go into
hold back position until the push rail is fully depressed

Plug raceway connector(s) into electric hinge connector(s) then feed through door prep

Note: Electric hinge will have two 8-pin connectors or two 8-pin and two 4-pin connectors

Mount electric hinge to door side only

Go to (A) if wiring now. Go to (B) if wiring is to be done later

A. Determine which Remote Options need to be wired per facility requirement

Refer to Remote Options Table and Wiring

Wire to loose wires on pigtail harness(es) as required using connectors allowed

by local code. Plug pigtail harness connector(s) into electric hinge connector(s)

Feed harnesses through frame prep and mount electric hinge

Ensure wiring is correct then apply power and test exit device

Refer to page 6 of this instruction and instruction A7224B for rail operating instructions

B. Plug pigtail harness connector(s) into electric hinge connector(s)

Feed harness(es) through frame prep and mount electric hinge

1

2

3

4

Pigtail harness assemblies

with 8 & 4-pin connectors

(shown). Pigtail harnesses

with 8-pin connectors only

may be supplied depending

on application

Raceway harness with

8 & 4-pin connectors

and 3 loose wires

4

AL- 80 Series Rail

with 8 & 4-pin

connectors

2

1

Mounting

bracket

1" dia

hole

in door

Screw

location

3

Electric hinge with 8 &

4-pin connectors (shown).

Electric hinge with 8-pin

connectors only may be

supplied depending on

application

Standard mounting bracket

Flush mount type

mounting bracket

*Refer to step 2 and select

appropriate mounting bracket