J. Operational Notes (Refer to this instruction and instruction A7224B)

Once power is connected, turning the key clockwise activates the alarm. A field settable time delay
of 7, 10, 15 or 20 seconds (refer to Instruction Manual A7224) is initiated prior to the rail going into
armed state. This delay allows the individual who is setting the alarm, time to exit without setting off
the alarm. The LED will flash yellow during this time.

Once the unit is armed, the horn will chirp one time and the LED will flash green and repeat every
30 seconds to indicate the unit is armed. Once armed, depressing the push bar will sound the
alarm. The rail alarm will sound until it is disarmed by one of three methods.

(1) Using a rail cylinder key,

(2) Remote reset/arm switch signal, or

(3) It will automatically reset after an optional field settable time delay of 2, 5, 10 minutes.

The LED will flash Red every 30 seconds to indicate the rail has been violated and will continue
to flash Red until the unit has been reset manually. If battery powered and low battery voltage is
detected, the horn chirps quickly and repeats every 10 seconds until the battery is replaced.