I. wiring to al- 80 series remote options – SARGENT AL - Alarmed Exit User Manual

Page 5

Advertising
background image

5

Electric Hinge with

8 & 4-pin connectors (shown)

or Electric Hinge with 8-pin

connectors only. See note 2

Raceway harness with

8 & 4-pin connectors

Notes:
1. Pigtail assemblies, electric hinge, raceway harness and rail connector terminations and wire colors all match

2. An electric hinge with 8-pin connectors only or 8 & 4-pin connectors is required depending on which Remote Options are required

A. Remote Options requiring an Electric Hinge with 8-pin connectors only :
RM - Remote Monitior
REX - Request to Exit
RP - Remote Power

B. Remote Options requiring an Electric Hinge with 8 & 4-pin connectors :
RR - Remote Reset
DS - Door Status (Tamper) with

or without options listed in A

3. Wire to pigtail harness assemblies per facility requirement

Pigtail harness #1

assembly with

8-pin connector

Pigtail harness #2

assembly with

4-pin connector

1

4 2

3

AL- 80 Series Rail

with 8 & 4-pin

connectors

(RP, +9) Red, 2

1

7 5

6 4

3

2

8

(RP, -9) Black, 1

(REX) Orange, 5

(REX) White, 3

(RM - NC) Brown, 8

(RM - C) Blue, 6

(RM - NO) Yellow, 7

I. Wiring to AL- 80 Series Remote Options

(RR) Violet, 1

(DS) Tan, 4

(RR) Grey, 2

(DS) Pink, 3

Hardwire RP (remote power)
& EG (Earth Ground) to
3267 (9vdc) Power Supply
if required. Refer to 3267
instruction A7477

Green (EG), 4

RM - Remote Monitor
REX - Request to Exit
EG - Earth Ground
RP - Remote Power
DS - Door Status (Tamper)
RR - Remote Reset

A7251C

Copyright © 2004, 2006, 2008, 2009, 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.

Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

Advertising