SARGENT 776 Controls User Manual

General description installation instructions

Advertising
background image

General Description

INSTALLATION INSTRUCTIONS

773, 774, 775, & 776 Electromechanical Exit Trim Solenoid
Locks & 54-Prefix (Lever Monitor Switch) to ElectroLynx™
Connector System

This manual includes instructions for wiring all 700 series electromechanical trims to the
ElectroLynx connector system. The correct wiring configuration must be selected depending
on type and function of the trim being installed. Refer to table of contents to select appropri-
ate wiring instruction for product being installed.

Important

• Disconnect all input power before beginning installation to prevent electrical shock and equipment damage
• Installer must be a trained, experienced service person
• All wiring must comply with applicable local electrical codes, ordinances and regulations

CAUTION:

The DC voltage applied to the lock must not exceed 13.5VDC for 12 Volt models and 27VDC for

24 Volt models. If the voltage exceeds these values, the solenoid may be damaged.

Specifications / Functions

Solenoid
Type: 12 or 24VDC, Intermittent or Continuous Duty
Current draw is .50Amp @ 12VDC and .25Amp @ 24VDC
Built-in full wave bridge rectification

Fail Safe Models:

773 without cylinder
775 with cylinder

Fail Secure Models:

774 without cylinder
776 with cylinder

54- (prefix for lever monitor switch) The switch monitors outside lever rotation.

Switch contact rating: 2Amp max @ 30VDC.

1 1-800-810-WIRE • www.sargentlock.com • A7725B

Copyright © 2013, Sargen

t Manufacturing Company

, an A

SS

A AB

LO

Y G

roup company

. All right

s reser

ved

.

Reproductions in whole or in par

t without express writ

ten permission of Sargen

t Manufacturing Company is prohibited

.

3/4/13

Advertising
This manual is related to the following products: