Update fan motor, Recover motor fittings, Release impeller – Great Plains PTO Kits Single-Section User Manual

Page 35: Recover motor fittings release impeller

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Appendix A - Installation

31

2014-06-16

Table of Contents

Index

401-885M

Update Fan Motor

If not installing a 401-956A fan motor update, continue at
Install Fan Cooler” on page 37.

Recover Motor Fittings

Refer to Figure 27
Note: The recirculation loop hose

is likely to be full of

oil. Have the oil collection bucket and a rag at hand.
Disconnect the higher of the two JIC connections
first.

23. Remove and save one each:

811-088C AD 3/4MORB 3/4MJIC

810-037C VALVE LINE CHECK

811-077C TE 3/4MORB 3/4MJIC 3/4MJIC

811-078C TE 3/4MJIC

841-196C HH1/2R2 024 3/4FJIC

and two:

811-150C EL 3/4FJIC 3/4MJIC

The remaining fittings are not re-used.

Release Impeller
If not installing a 401-956A fan motor update, continue at
Install Fan Cooler” on page 37.

Refer to Figure 28
24. Locate the impeller hub bushing:

890-891C BUSHING, JA X 20 MM

inside the fan housing. Remove three:

HHCS #10-24x1 INCH GRADE 8 FULL THREAD

25. Thread the cap screws

into the threaded holes

in the bushing

. Screw them in until they contact

the impeller. Drive them one turn at a time, in a
rotating pattern, until the bushing is free. Recover
and save the bushing, screws and one:

800-373C SQ KEY 6MM X 35MM

The impeller may now be loose inside the fan
housing.

The bushing and screws are not reused.

Figure 27:

Recover Fittings

34631

39

35

32

39

47

37

34

47

37

32

34

35

47

39

Figure 28:

Fan Impeller Hub Bushing

34683

11

1

52

19

52

11

11

1

52

19

Advertising