Install controls on fan mast – Great Plains PTO Kits Single-Section User Manual

Page 53

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Appendix A - Installation

49

2014-06-16

Table of Contents

Index

401-885M

Install Controls on Fan Mast

This page applies only to kits 401-845A, 401-846A,
401-879A, 411-163A, 411-164A, and 411-168A. For
other kits, find the topic starting page in the table on
page 48.

Refer to Figure 57 (a view from below right front)
87. Remove and save the two forward flanged:

803-360C NUT HEX FLG 3/8-16 GR8 ZNYCR

88. Select one new:

401-835S RIGID PLNTR HYD FL CNTRL ASSY

The valve assembly has port letters stamped on the
valve body. Orient the assembly so that ports M & T
are on top, and ports T & P are on the bottom.
Secure the valve assembly to the air tank U-bolts
with the saved nuts

.

Continue at “Install Hoses” on page 54.

U

D

B

F

L

R

124

27

Figure 57:

Flow Controls on Fan Mast

34666

27

124

27

Advertising