Dismount Fan
If not installing a 401-956A fan motor update, continue at
Install Fan Cooler” on page 37.

Refer to Figure 29
26. Disconnect the duct hose at the outlet

(duct not

shown).

27. At the mount plate

, remove and save one:

801-081C SCREW HEX SELF TAP 1/4-20X3/4

28. Prepare to support the weight of the fan assembly,

which may be as much as 70 pounds (32 kg).

29. At the fan mount weldment

, starting at the

bottom, remove and save five:

804-006C WASHER LOCK SPRING 1/4 PLT

802-224C HHCS 1/4-20X1 1/4 GR5

The fan/motor assembly is now loose. Move it to a
workbench or similar flat surface, with the fan inlet
facing down.

Remove 3-Port Hydraulic Motor
If not installing a 401-956A fan motor update, continue at
Install Fan Cooler” on page 37.

Refer to Figure 30
30. Remove and save two:

803-014C NUT HEX 3/8-16 PLT

804-013C WASHER LOCK SPRING 3/8 PLT

four:

804-011C WASHER FLAT 3/8 USS PLT

two:

802-079C HHCS 3/8-16X1 1/4 GR5

The following items are not reused:

890-899C VOLVO HYD MOTOR MOUNT PLT

23907 HUB/MOTOR PLATE SEAL (2B)

810-556C PARKER F-11 FAN MOTOR

Figure 29:

Dismount Fan

34681

16

24

28

2

53

20

2

53

20

16

28

24

Figure 30:

Remove 3-Port Motor

34680

22

15

29

30

53

25

29

33

25

30

29

22

53

15

33

Advertising