Reservoir on mainframe truss – Great Plains PTO Kits Single-Section User Manual

Page 49

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Appendix A - Installation

45

2014-06-16

Table of Contents

Index

401-885M

Reservoir on Mainframe Truss

This topic applies only to kits 401-879A and 411-168A,
and planter models:

For other kits, find the topic starting page in the table on
page 41.

Refer to Figure 52 and Figure 53
The truss-mount reservoir location is used with 3-point
“wide row” planters that have a truss weldment

above

the mainframe tool bar. It applies to kits 401-879A and
411-168A, which have the following component unique
to the truss location:

401-878L 3PT 8 ROW WIDE HYD RES W/FLTR

This tank weldment has two mount plates

(front- and

rear-facing) and straight bolts, designed to straddle the
truss tube.

78. Select one new:

401-878L 3PT 8 ROW WIDE HYD RES W/FLTR

and four sets new:

802-377C HHCS 1/2-13X7 1/2 GR5

804-015C WASHER LOCK SPRING 1/2 PLT

803-020C NUT HEX 1/2-13 PLT

If the fasteners are pre-installed in the reservoir
assembly, completely remove them.

79. With the front face (which has the sight gauge

)

facing forward, lower the reservoir weldment down
over the right side of the truss tube, at a distance of:

27 inches (68.6 cm)

from hitch center-line to reservoir mount center-line.

80. Insert two bolts

through the holes of the

weldment plates, underneath the truss tube.

Secure the bolts with lock washers

and

nuts

.

Continue at “Install Flow Control Valve” on page 48.

YP825A3P-0836

YP825A3P-1636

YP825A3P-1640

YP825A3P-0838

YP825A3P-1638

YP825A3P-0840

Figure 52:

Truss-Mount Reservoir 401-878L

34663

140

166

173

169

2

4

1

140

2

3

140

1

U

D

F

B

L

R

Figure 53:

Reservoir to Truss

34664

140

166

173

169

4

161

173

169

Advertising