Point row troubleshooting – Great Plains 3N-4025P Operator Manual User Manual

Page 133

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Troubleshooting

129

2014-01-29

Table of Contents

Index

196-538M

Point Row Troubleshooting

Drill does not fold or
unfold fully

Rephase cylinders, refer to page 145.

Bleed fold circuit, refer to page 146.

Adjust fold cylinders, refer to page 146.

Drill wanders back and
forth in transport

Use all locks.

Adjust tongue shims on rub blocks or
frame spacers, refer to page 144.

Adjust fold cylinders, refer to page 146.

Problem

Cause

Solution

no seed
metering, all
rows

fuse blown

Check fuse. Correct
underlying fault before
replacing fuse.

height switch
not tripping

Check adjustment of
height switch.

no metering,
one section

clutch failure Lock-up clutch until

repaired or replaced.

shearing

Replace

1

4

-20 bolts and

1

4

inch roll pins in clutch

assembly.

seed rate low
or uneven

lubricant in
clutch

Disassemble and
degrease clutches.

meters
always on

CAL mode
on

Move Master switch
handle from CAL to ON.

height switch
always on

Check adjustment of
height switch.

Problem

Cause

Solution