Great Plains 3N-4025P Operator Manual User Manual

Page 55

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Hydraulic Drive Operation

51

2014-01-29

Table of Contents

Index

196-538M

Refer to Figure 65
38. When the sample run-time has expired, the motor

stops, the indicator above the ENGAGE button goes
out, and the console displays the estimated sample
generated (based on actual motor performance,
which may vary slightly from calculations).

The number display is normally very close to the
sample size entered at step 30.

39. Exit the tractor cab and obtain the net weight of the

samples. If multiple rows were sampled, divide the
total seed weight by the number of row sampled.

Refer to Figure 66
40. Enter the actual amount metered per row using the

⇑/⇓ arrow buttons.

Press FUNCTION button to advance to next window.

Figure 65

Cal. Mode Normal Completion

28261

Example:
Three 4 oz. containers were used at 3 rows.
ContainerWeight = (4 x 3 /16), or
0.75 lbs.

Weight of containers and metered seed was:
GrossWeight = 3.66 lbs.

SampleWeight = 3.66 - 0.75, or
2.91 lbs.

AmountedCollected = 2.91 / 3, or
0.97 lbs.

SampleWeight

GrossWeight

ContainerWeight

=

AmountCollected

SampleWeight

RowsSampled

----------------------------------

=

Figure 66

Cal. Mode Enter Seed Count

28262

Advertising