Row unit shut-off, Seed meter setup and adjustment, 10hd, 25 series meter removal – Great Plains 3N-4025P Operator Manual User Manual

Page 83: 79 f

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Adjustments

79

2014-01-29

Table of Contents

Index

196-538M

Row Unit Shut-Off

To shut off seed flow to individual rows, such as to
operate with an alternate row spacing, there are two or
three steps involved:

Refer to Figure 97
1.

Block the seed flow to the row with an optional seed
tube plug. See page 163 for ordering.

2.

Re-calculate the drill’s swath, and check for any
changes needed to:
• marker extension (see pages 21 and 176) and
• calibration (step 15 on page 45).

3.

On 10HD and 25 Series, reduce needless wear on
the unused rows by locking them up. See page 105.

Seed Meter Setup and Adjustment

Your Drill was originally supplied with a specific seed
meter type and internal components optimized for a
particular crop. Depending on the meter type and
configuration, there may be adjustments available.

On 10HD and 25 Series openers, you can also entirely
change the meter as your crop mix changes.

All models support:

• Great Plains Singulator Plus™ meters

The 3N4010HDP and 3N4025 further support:

• Finger pick-up meters.

The 3N-40P does not support feeder cups. Use a
Singulator Plus™ meter with specific wheels for
volumetric applications.

10HD, 25 Series Meter Removal
Note: Applies only to 10HD and 25 Series openers.

1.

Clean out meter.

Refer to Figure 98
2.

Slide the retaining ring up on the seed hose, and
remove the seed hose.

Refer to Figure 99
3.

Release the lower latch.

Figure 97

Block Seed Tubes

26226

Figure 98: 10HD, 25 Series:

Seed Hose Retaining Ring

22883

Figure 99: 10HD, 25 Series:

Lower Meter Latch

22911

Advertising