Precision Population Settings
1.

Connect PF3000 to Console using 9 pin serial cable
per Figure 86 on page 59.

2.

Set Calibration Number per page 42.

Refer to Figure 87
3.

Press FUNCTION button until a “recipe” screen
appears. Use the

⇑/⇓ arrow buttons to select

RAWSON mode.

Refer to Figure 88
4.

Press FUNCTION button until the Nominal Rate
appears on the display.
Using the

⇑/⇓ arrow buttons, set the Nominal Rate to

the same number as you set the PF3000 in step 5
above. Once Nominal Rate is set, press FUNCTION
key until main operating screen appears.

5.

Press On/VR key again to toggle to VR mode. VR
should appear on the screen along with the Rate that
is being sent from the PF3000. Verify that the rate
shown on the GP Controller Console is the same as
the recipe sent from the PF3000.

Press ENGAGE button to activate the Precision
Population Controller.

6.

To change rates manually when in VR mode, simply
touch the

⇑/⇓ arrow buttons. This changes the

Controller to the rate you select manually. To return
to VR, touch the ON/VR button to toggle back to VR
mode.

Figure 87: PF3000:

Rawson Recipe Mode

28320

Figure 88: SiteMate:

Rawson Nominal Rate

28323